Mobile QR Code QR CODE : Journal of the Korean Society of Civil Engineers

References

1 
ACI 355.2 (2001), Evaluating the Performance of Post-Installed Mechanical Anchors in ConcreteGoogle Search
2 
ACI 355.2 (2019), Qualification of Post-Installed Mechanical Anchors in Concrete and CommentaryGoogle Search
3 
ACI 318 (2019), Building Code Requirements for Structural ConcreteGoogle Search
4 
ACI 349 (2024), Code Requirements for Nuclear Safety-Related Concrete Structures and CommentaryGoogle Search
5 
ASTM E488 (2018), Standard Test Methods for Strength of Anchors in Concrete ElementsGoogle Search
6 
Bang J. S., Kwon Y. S., Ahn J.-H., Yim H. J. (2022). "Pull-out behavior evaluation of torque-controlled expansion anchors under various installation conditions of concrete", Case Studies in Construction Materials, Vol. 16DOI
7 
Delhomme F., Pallud B., Rouane N. (2018). "Tightening torque influence on pullout behavior of post-installed expansion anchors", KSCE Journal of Civil Engineering, Vol. 22, No. 10, pp. 3931-3939DOI
8 
ICC-ES (2025), Hilti HSL4 carbon steel heavy duty expansion anchors for cracked and uncracked concreteGoogle Search
9 
Huda A., Apriyatno H. (2021). "Experiment of pullout expansion anchor in installation: Cast in place and post installed with concrete breakout failure", Jurnal Teknik Sipil & Perencanaan, Vol. 23, No. 1, pp. 37-45DOI
10 
Hur M.-W., Chae K.-H., Lee H.-H., Park T.-W. (2024). "Performance evaluation of torque-controlled expansion anchors with improved sleeve and header details", International Journal of Concrete Structures and Materials, Vol. 19DOI
11 
Kim S.-Y., Lee S.-K., Kwon H.-W., Lee H.-S., Yang M.-H. (2001). "Sleeve-type expansion anchor behavior in cracked and uncracked concrete"Google Search
12 
Kim S.-Y., Seo S.-Y., Kim K.-S. (2003). "Tensile strength of expansion anchors installed in uncracked and unreinforced concrete", Steel Construction Engineering, Vol. 19, No. 11, pp. 83-92Google Search
13 
Kim J.-S., Kwon M.-H., Seo H.-S., Park J.-H. (2013). "Performance evaluation and analysis model for the post-installed anchor", Journal of KOSHAM, Vol. 13, No. 2, pp. 89-95DOI
14 
Kim J.-G., Chun S.-C., An Y.-S. (2022). "Pullout tests on M12&M20 stainless steel post-installed expansion anchor for seismic design in cracked concrete", Journal of the Korea Institute for Structural Maintenance and Inspection, Vol. 26, No. 1, pp. 29-38DOI
15 
Konieczny K., Dudek D., Kukielka A. (2024). "Expansion and bonded anchors in (shallow) fixings in concrete substrate reinforced with steel and polypropylene fibres", MATEC Web of Conferences, Vol. 396DOI
16 
Korea Institute of Nuclear Safety (KINS) (2017), Investigation Report on the Effects of the 2016 Gyeongju Earthquake on Nuclear Power Plant FacilitiesGoogle Search
17 
Lee S., Jung W. (2021). "Evaluation of structural performance of post-installed anchors embedded in cracked concrete in power plant facilities", Applied Sciences, Vol. 11, No. 8DOI
18 
Nemes R., Lublói É. (2011). "Application of anchors under special concrete conditions", Periodica Polytechnica Civil Engineering, Vol. 55, No. 1, pp. 73-79DOI
19 
Nuclear Regulation Authority (NRA) (2013), Technical Lessons Learned from the Great East Japan Earthquake and the Fukushima Daiichi Nuclear AccidentGoogle Search
20 
Spyridis P., Mellios N. (2022). "Tensile performance of headed anchors in steel fiber reinforced and conventional concrete in uncracked and cracked state", Materials, Vol. 15DOI