Mobile QR Code QR CODE : Journal of the Korean Society of Civil Engineers
Title Analysis and Evaluation of the Effect of Blast-induced Vibration Adjacent to Industrial Facilities
Authors 곽창원(Kawk, Chang Won) ; 박인준(Park, Inn Joon) ; 김영준(Kim, Young Jun)
DOI https://doi.org/10.12652/Ksce.2023.43.4.0459
Page pp.459-468
ISSN 10156348
Keywords 발파진동; 발파진동 허용 기준; 동적수치해석; 입자진동속도; 발파패턴 Blast-Induced vibration; Allowable vibration criteria; Dynamic numerical analysis; Particle velocity; Blasting pattern
Abstract Power plant is a kind of basic industrial facility and might cause fatal industrial and human damage. In this study, the characteristics and effect of blast-induced vibration for tunnelling which underpass ○○ power plant in operation were evaluated. Previous blasting cases adjacent to industrial facilities were intensively reviewed, then allowable vibration criteria were suggested. 3 dimensional dynamic numerical analysis based on finite element method was performed to investigate particle velocity and resonance was examined by calculating the predominant frequencies. As a result, particle velocity at pump foundation which is nearest to the source was approached to the allowable criteria, therefore, the modified blasting pattern was newly suggested and confirmed the attenuation effect based on the test blasting. Consequently, appropriated decision-support procedure was established in case of adjacent blasting to industrial facilities.